905U-D Radio Modem User Manual
Man_905D_1.10.doc Page 60
Radio will not transmit until the number of
characters in the input buffer = 2 x S18
value - see below
Input buffer delay override
Override time in msec to override S18 delay
- see below.
Radio message signature /
lead-in tones
default = 1
set to 0 for old systems, set to 2 or 3 for
new systems suffering interference from
other 905U systems
S18 is calculated as S18 = (MP – (SR * (10*MP/RB + TD)) / 2 (Rounded up)
SB is serial baud Rate, (in bits per second)
SR is serial data Rate, (in bytes per second – usually 1/10
th
of SB)
RB is radio baud Rate, (in bits per second)
TD is transmit delay (0.028 for transparent/controlled mode, 0 for fast controlled mode)
MP is the maximum packet size to be transferred
NB is the maximum number of bit times delay allowed between characters in the protocol.
S19 is calculated as S19 = 1000 * (NB/SB) (Rounded up)