905U-D Radio Modem User Manual
Man_905D_1.10.doc Page 58
&N1
If a key is hit or a character input while attempting to connect, abort the
connection attempt and return to command mode.
AT&S
Set module’s System Address Range 0-255.
AT&T
Self Tests. Allows in-field diagnostics, and factory testing.
&T0
Transmit Bit Error Rate Test. Generates pseudo random data and sends out radio.
&T1
Receive Bit Error Rate Test. Receives data from &T0 module, and records BER
statistics.
&T2
Transmit & Receive BER Test. Used with a second module configured as a
transparent repeater.
&T3
RSSI Measurement. Monitors the received signal strength, and displays in dBm.
AT&V
View Current Configuration – List the value of all settings as well as S-Registers.
&V0
Same as AT&V
&V1
Only show settings that are different from the defaults.
AT&U
Set module’s Unit Address Range 0-127. Default 1.
AT&W
Write Current Configuration to non-volatile storage
AT&Z
Stored Numbers – Up to 4 destination addresses may be stored.
Format: “AT&Zx=nn,nn,nn,nn”. “x” = 0 to 7. “nn” = 1 to 127.
AT&Z0 is used for auto-connect address.
AT\T
Inactivity Timeout – Units Seconds. Value 0-255. Default = 0 (disable). If there is
no radio activity in controlled mode within this time, the module resets the
connection. If used, should be larger than the value in S6.
S-Registers
S-Registers provide a method of storing operational parameters of the module. A radio module
has different requirements to a telephone module, so functions of the S-Registers are also
different. S-Registers may be examined using the command ATSn?, where n is the number of the
S-Register. S-Registers may be modified using the command ATSn=xx, where n is the S-
Register number, and xx is the new value for the register.
S-Registers and functions are listed below:
No.
Range
Function
Comment
S0
0-255
Number of attempts before
answering connection
message
Should normally be set to 1 - 0 disables
auto answering of calls (ATA only).
S1
3-255
Escape Sequence Guard
Time (Units 20 milliseconds)
default = 50
Min. Delay before and after entering the
escape sequence - also Max. Delay
between characters of the escape sequence.
S2
1-255
Escape Sequence Character
Normally 43 = “+”